Autoinjector and Injection Pen Platforms

Seven platforms across four device types: fixed-dose autoinjectors that deliver one prefilled syringe per activation, adjustable disposable pens that dose a cartridge in dialled steps, reusable pens — one of them dual-chamber, for in-device reconstitution — and single-use pen injectors. Every specification below comes from the factory's controlled data; the drug names are application examples — the devices ship empty and carry no therapeutic claims. Container fit is verified per program on the compatibility page.

Platform overview

PlatformTypeContainerDoseDesigned for
Disposable autoinjector — prefilled syringeFixed-dose1.0 mL slender PFS · 2.25 mL PFS0.2–1.0 mL · 0.2–2.25 mL per activationTirzepatide, semaglutide, mAbs, epinephrine
Disposable autoinjector — multi-doseAdjustable3 mL · 1.5 mL cartridge (ISO 11608-3)0.01 mL min; 0.37–1.00 mL by configSemaglutide, tirzepatide, insulin degludec
UrgoPenFixed-doseCustom 2.25 mL cartridge (ISO 11608-3)0.15–2.0 mL fill; max 2.0 mLEpinephrine emergency use
Reusable autoinjector pen (WH-RG)Adjustable, reusable5 mL cartridge (ISO 11608-3)0.02 mL min; 50 incrementsSemaglutide, insulin series, growth hormone
Reusable dual-chamber penAdjustable, reusable, dual-chamber4 mL dual-chamber cartridge0.01–0.5 mL; 0.01 mL stepsLyophilized + diluent two-component drugs
A-75 pen injectorAdjustable, disposable3 mL cartridge (ISO 11608-3)1–75 IU (10–750 µL), 1 IU stepsSemaglutide programs
A-60 pen injectorAdjustable, disposable3 mL cartridge (ISO 11608-3)1–60 IU (10–600 µL), 1 IU stepsInsulin, GLP-1, growth hormone, aesthetic

1 · Disposable Autoinjector — Prefilled Syringe (Fixed-Dose)

WH-DF disposable autoinjector for prefilled syringes, white body with blue cap

One activation, one complete dose from a prefilled syringe. Built for biologics, biosimilars and emergency-use programs where the dose is set by the fill, not by the user.

Primary container1.0 mL slender-type PFS · 2.25 mL PFS
UsageDisposable, fixed-dose
Fill volume0.2–1.0 mL (1.0 mL PFS) · 0.2–2.25 mL (2.25 mL PFS)
Minimum deliverable0.2 mL
Maximum dose1.0 mL (1.0 mL PFS) · 2.25 mL (2.25 mL PFS)
Needle typeMatched to the pharmaceutical company's specification
Application examplesTirzepatide, semaglutide, monoclonal antibody drugs (1.0 mL PFS) · epinephrine, monoclonal antibody drugs (2.25 mL PFS)

2 · Disposable Autoinjector — Multi-Dose Cartridge (Adjustable)

WH-DG disposable multi-dose autoinjector, blue body, multiple views, white background

Takes standard 3 mL or 1.5 mL cartridges and doses in 0.01 mL steps. The factory builds it in several dosing configurations — one per titration schedule — and the configuration is fixed at order time.

Primary containerStandard 3 mL and 1.5 mL cartridge according to ISO 11608-3
UsageDisposable, adjustable-dose
Fill volume1.5–3 mL
Minimum deliverable0.01 mL (all configurations)
Maximum dose0.37–1.00 mL, set by configuration (see table)
Needle typeCompatible with standard pen needles according to ISO 11608-2
The dosing configurations — select one per order:
Application exampleCartridgeMin. unit doseDose unitsDose range
Semaglutide (1.5 mL)1.5 mL0.01 mL370–0.37 mL
Semaglutide (3 mL)3 mL0.01 mL740–0.74 mL
Tirzepatide3 mL0.01 mL600–0.60 mL
Insulin degludec/aspart3 mL0.01 mL800–0.80 mL
Insulin degludec/liraglutide3 mL0.01 mL500–0.50 mL
Insulin icodec3 mL0.0143 mL700–1.00 mL

3 · UrgoPen — Emergency Fixed-Dose Autoinjector

UrgoPen emergency autoinjector with cartridge, white background

A fixed-dose autoinjector built around a custom 2.25 mL cartridge, with the fill — not the user — setting the dose. Designed for epinephrine programs.

Primary containerCustom 2.25 mL cartridge according to ISO 11608-3
UsageDisposable, fixed-dose
Fill volume0.15–2.0 mL
Minimum deliverable0.15 mL
Maximum dose2.0 mL
Needle typeMatched to the pharmaceutical company's specification
Application examplesEpinephrine

4 · WH-RG Reusable Autoinjector Pen (Adjustable)

NOVIXPEN WH-RG reusable autoinjector pen with cartridge holder, white background

A reusable platform built around a 5 mL cartridge, dosing in 50 increments from a 0.02 mL minimum — sized for chronic therapies that run through large total volumes over the device's life. Housing colours, brand-colour matching, logo printing and a configurable dose-unit window are available.

Primary container5 mL cartridge, ISO 11608-3 compliant
UsageReusable, adjustable-dose
Minimum deliverable dose0.02 mL
Dosing increments50
Reference dosing configurationSemaglutide — 0.100 mL dose range on the 5 mL cartridge
Application examplesSemaglutide, tirzepatide, liraglutide, teriparatide, insulin glargine, insulin aspart, biphasic insulin aspart 30/25, NPH insulin, insulin degludec, insulin degludec + liraglutide, growth hormone
CustomizationStandard and brand-matched housing colours, logo printing, configurable dose-unit window, packaging for automated assembly

5 · Reusable Dual-Chamber Pen (4 mL)

NOVIXPEN reusable dual-chamber pen injector for 4 mL dual-chamber cartridges

Two components that must stay separated until use — typically a lyophilized cake and its diluent — live in one 4 mL dual-chamber cartridge. The pen integrates cartridge actuation, mixing travel, dose adjustment and injection into a single workflow, replacing separate transfer and manual mixing.

Primary container4 mL dual-chamber cartridge
UsageReusable, adjustable-dose, in-device reconstitution
Dose range0.01–0.5 mL
Minimum dose increment0.01 mL
WorkflowActuation → mixing travel → dose adjustment → injection, in one device
Designed forTwo-component drugs: separation before use, mixing in the device, then delivery

Final system performance depends on the cartridge architecture, chamber volumes, separation structure, mixing travel and fluid characteristics of your program — each configuration is evaluated with the actual cartridge and samples.

6 · A-75 Disposable Pen Injector (75 IU)

A-75 disposable pen injector pair, white bodies with orange caps

All-plastic disposable pen with dial-a-dose in 1 IU steps over a 1–75 IU range, taking standard 3 mL cartridges and Luer-interface pen needles. Designed around semaglutide dosing schedules.

NameDisposable all-plastic injection pen
ModelA-D2.7 (factory code AUTO-PD75A)
Service life5 years from production, or 300 activations
Net weight34 g
Diameter18.5 mm
Length181 mm
Dose range1–75 IU (10–750 µL)
Resolution1 IU (10 µL)
Dose accuracyISO 11608-1 compliant
Cartridge3 mL cartridge, ISO 11608-3 compliant
NeedleLuer pen needle, ISO 11608-2 compliant
Application examplesSemaglutide programs

7 · A-60 Disposable Pen Injector (60 IU)

A-60 disposable pen injector, white body with blue cap, inner cartridge shown

The 1–60 IU variant of the same all-plastic platform, covering insulin, GLP-1, growth hormone and aesthetic-injection dosing schedules on the identical mechanical envelope.

NameDisposable all-plastic injection pen
ModelA-D2.1 (factory code AUTO-PD60A)
Service life5 years from production, or 300 activations
Net weight34 g
Diameter18.5 mm
Length181 mm
Dose range1–60 IU (10–600 µL)
Resolution1 IU (10 µL)
Dose accuracyISO 11608-1 compliant
Cartridge3 mL cartridge, ISO 11608-3 compliant
NeedleLuer pen needle, ISO 11608-2 compliant
Application examplesInsulin, GLP-1, growth hormone, aesthetic injections

Reading these tables

How to verify us

Every figure on this page exists in a controlled specification sheet we can send on request, and every compliance line (ISO 11608-1/-2/-3) has a test report behind it — released with the order documentation, see compliance. Ask for the sheet with its revision number before any design decision.

What the drug names do and do not mean

Application examples describe the dosing parameters the platform was designed around. The devices ship empty: they contain no drug, and naming a drug is not a therapeutic claim, an effectiveness statement or a recommendation. Drug registration is the pharmaceutical company's work; ours is a documented device that fits its container and dose schedule.

Match a platform to your program

Send your container format, dose schedule and target market. We return the matching platform, its controlled specification sheet and the applicable MOQ within one working day.

Start the match